Fanuc R-30IA
84 códigos de falla documentados
Emergency Stop Circuit 24V Fault
The 24EXT (Red) LED turning on indicates that the fuse (FUSE2) is blown, and the 24V external power supply (24EXT) for the emergency stop circuit is not being supplied. This impacts the integrity and functionality of the emergency stop line, posing a safety risk.
Teach Pendant 24V Fault
The 24T (Red) LED turning on indicates that the fuse (FUSE3) is blown, meaning the 24V power supply (24T) for the teach pendant is not being supplied. This prevents the teach pendant from operating correctly, interrupting robot control.
FILE-002 Device is Full
The PROG_BACKUP operation failed because the required disk space to backup programs exceeded the available space on the target device. This results in a 'Device is Full' error, and a partial backup may exist. The return status for the PROG_BACKUP routine will be 2002.
File is not opened
An attempted file operation failed because the specified file_id does not correspond to an opened file or one of the pre-defined files (CRT/KB, teach pendant, vision windows). This IO_STATUS error indicates an attempt to perform an operation on an inactive or non-existent file context. The program will abort if the file_id is invalid.
Cannot write the variable
An attempt to write a KAREL program variable to an opened file failed. This IO_STATUS error indicates a problem during the variable writing process, possibly due to data incompatibility or file access issues. The program will abort if the file_id is invalid.
Write file failed
A general failure occurred during a file write operation. This IO_STATUS error suggests an underlying issue that prevented data from being successfully written to the file associated with the file_id. The program will abort if the file_id is invalid.
Cannot read the variable
An attempt to read a KAREL program variable from an opened file failed. This IO_STATUS error indicates an issue during the variable reading process, possibly due to file corruption or incorrect data type matching. The program will abort if the file_id is invalid.
Read data is too short
During a file read operation, the amount of data read was less than expected or required for the variable. This IO_STATUS error often indicates a truncated file, end-of-file condition, or a mismatch between the expected data size and available data. The program will abort if the file_id is invalid.
Illegal ASCII string for read
An attempt to read an ASCII string from a file encountered invalid or malformed data that does not conform to the expected ASCII string format. This IO_STATUS error signifies data corruption or an incorrect file format when attempting string conversion. The program will abort if the file_id is invalid.
Read file failed
A general failure occurred during a file read operation. This IO_STATUS error indicates an underlying issue that prevented data from being successfully read from the file associated with the file_id. The program will abort if the file_id is invalid.
Cannot open pre_defined file
An attempt to open a pre-defined KAREL file (such as CRT/KB, teach pendant, or vision windows) failed. This IO_STATUS error indicates an issue with accessing these standard system I/O channels. This could be due to resource contention or system misconfiguration.
Cannot close pre_defined file
An attempt to close a pre-defined KAREL file (such as CRT/KB, teach pendant, or vision windows) failed. This IO_STATUS error indicates an issue preventing the proper release of these standard system I/O channels. This could leave the resource in an indeterminate state.
Close file failed
A general failure occurred during a file close operation. This IO_STATUS error indicates an underlying issue that prevented a file associated with the file_id from being properly closed and its system resources released. The program will abort if the file_id is invalid.
Read I/O value failed
An attempt to read an I/O value from an external device or internal register failed. This IO_STATUS error indicates a problem accessing or retrieving data from an I/O device or address. The program will abort if the file_id is invalid.
Write I/O value failed
An attempt to write an I/O value to an external device or internal register failed. This IO_STATUS error indicates a problem sending data to an I/O device or address, preventing control signals or data from being sent. The program will abort if the file_id is invalid.
Timeout at read request
A read request to an I/O device or file timed out before the operation could complete, indicating that the system waited longer than the allowed period for a response. This IO_STATUS error suggests a communication issue, a slow device, or an unresponsive file system. The program will abort if the file_id is invalid.
Read request is nested
A read request was initiated while another read request was already active for the same resource or file_id. This IO_STATUS error indicates an attempt to perform concurrent read operations which is not supported or allowed for the specific resource. The program will abort if the file_id is invalid.
Bad base in format
An invalid or unrecognized numeric base was specified within a format string during an I/O operation (e.g., for numeric conversions to or from strings). This IO_STATUS error typically occurs when parsing or formatting data, indicating a syntax error in the format specification. The program will abort if the file_id is invalid.
Broken Wire or Noise (Subsequent Unit)
The red ALM LED blinks with a 1:1 duty cycle (0.5s ON / 0.5s OFF), indicating a broken wire or poor cable connection between the unit of interest (JD1A connector) and a subsequent unit (JD1B connector). Electromagnetic noise around the cable is also a potential contributing factor to this communication issue.
Status Alarm (DO Ground Fault)
The red ALM LED blinks with a 1:3 duty cycle (0.5s ON / 1.5s OFF), indicating a general status alarm. A common example of such a status alarm is a Digital Output (DO) ground fault.
Power Failure (Subsequent Unit)
The red ALM LED blinks with a 3:1 duty cycle (1.5s ON / 0.5s OFF), indicating a power failure (which may include instantaneous power failure) in a unit subsequent to the unit of interest. This signifies a power supply interruption downstream from the current unit.
Hardware Defect Alarm
The red ALM LED is continuously illuminated, signifying an alarm within the unit of interest or a subsequent unit. This condition strongly suggests a hardware defect within the affected unit.
Communication Halted by Alarm
The Common LED blinks rapidly (0.25s ON / 0.25s OFF), indicating that communication is halted due to an active alarm condition. Further investigation of other alarm indicators is required to pinpoint the specific cause.
Servo Amplifier Not Ready
The DRDY (Green) LED indicates that the servo amplifier is ready to drive the servo motor. This fault occurs if the LED does not light when the motor is activated, suggesting the servo amplifier is not reaching a ready state to control the motor.
Force Sensor Communication Error
The ER0, ER1, or ER2 LEDs illuminate when an error occurs in communication with the force sensor. This indicates a potential issue with the sensor's interface unit or its connection cable.
Fuse Blown
The FUSE LED illuminates when an internal fuse blows. This typically indicates an overcurrent condition that has resulted in the protective fuse activating.
FSSB Communication Error
The OPEN (Green) LED indicates normal communication between the servo amplifier and the main board via FSSB. This fault occurs if the LED does not light, indicating a loss or abnormality in this critical communication link. This could be due to a faulty optical cable, servo card, or the servo amplifier itself.
+3.3V Power Supply Fault
The P3.3V (Green) LED indicates that the internal power supply circuit of the servo amplifier is normally outputting +3.3 V. If this LED does not light, it signifies a failure in the +3.3V power supply within the servo amplifier, which is critical for its internal logic.
+5V Power Supply Fault
The P5V (Green) LED indicates that the internal power supply circuit of the servo amplifier is normally outputting +5 V. If this LED does not light, it signifies a failure in the +5V power supply within the servo amplifier, or a ground fault on the +5V wire of the robot connection cable (RP1/RMP1).
Pneumatic Pressure Alarm
An abnormal air pressure condition has been detected. This input signal is typically located on the end effector (EE) interface of the robot, indicating an issue with the pneumatic supply to or within the robot's tooling.
Brake Abnormal
An excessive current is detected in the motor brake circuit, and the ALM LED (SVALM) on the 6-Axis servo amplifier is illuminated. This can be caused by a short circuit or ground fault in the brake wiring, or an optional brake release unit being left active while attempting robot motion.
SRDY Signal Off
The HRDY signal is ON, but the SRDY signal is OFF, indicating that the servo amplifier magnetic contactor cannot be turned on for an unknown reason. This occurs when the host commands the servo system (HRDY) to turn on the magnetic contactor, but the servo system (SRDY) fails to confirm it, without any other specific servo amplifier alarm being present.
SRDY Signal On Prematurely
The SRDY signal is already ON when the HRDY signal is about to go ON. This means the servo system is indicating that the magnetic contactor is engaged before the host controller has commanded it to do so, suggesting an internal fault in the servo amplifier's control circuit.
Excessive Position Error at Stop
When the servo is commanded to stop, the actual position error is abnormally large. This can occur if the motor brake fails to release properly, or if there is a physical obstacle preventing the robot from maintaining its commanded stop position.
Pulsecoder Serial Data Error
The serial Pulsecoder fails to return serial data in response to a request signal. This indicates a communication fault between the servo amplifier and the Pulsecoder, potentially due to loose connections, damaged cabling, or a faulty Pulsecoder itself.
Pulsecoder Serial Data CRC Error
The serial data transmitted from the Pulsecoder was disturbed during communication, resulting in a Cyclic Redundancy Check (CRC) error. This indicates data corruption, which can be caused by electrical noise, poor shielding, or faulty communication components.
Pulsecoder Serial Data Start/Stop Bit Error
The start and stop bits of the serial data received from the Pulsecoder are abnormal. This indicates a communication framing error, often pointing to issues with data transmission integrity, such as signal distortion or timing discrepancies.
Abnormally High Feedback Speed
The feedback speed reported by the motor's Pulsecoder is abnormally high, exceeding expected operational limits. If this alarm occurs concurrently with the SRVO-064 (PHAL alarm), SRVO-064 is considered the primary cause.
Pulsecoder Malfunction
This alarm indicates that the Pulsecoder is likely abnormal, suggesting a internal malfunction or failure of the feedback device itself. This can lead to incorrect position and speed feedback.
CMAL alarm (Pulsecoder Abnormality)
This alarm (Group:i Axis:j) indicates that the Pulsecoder is likely abnormal or has malfunctioned due to electrical noise. This can lead to incorrect or unstable position feedback for the associated axis, causing control instability or position errors.
LDAL alarm (Pulsecoder LED Broken)
This alarm (Group:i Axis:j) signifies that the LED within the Pulsecoder is broken or faulty. This prevents the Pulsecoder from generating proper position feedback, directly affecting axis control and potentially leading to inaccurate positioning or uncontrolled motion.
Pulse Not Established
This alarm (G:i A:j) indicates that the absolute position of the Pulsecoder cannot be established. This typically occurs during startup or after a power cycle if the encoder's absolute position data is lost or corrupted, preventing the robot from determining its current joint angles.
Tip Stick Detection
This alarm (G:i A:j) indicates that an excessive disturbance was assumed in the servo software at the start of operation, detecting an abnormal load. Possible causes include a robot collision, increased mechanical load on the axis, or issues like welding interference. This poses a risk of mechanical damage or operational halt.
Line Tracking Encoder Overflow
The pulse counter for the line tracking encoder has overflowed. This typically occurs if the conditions for line tracking operation exceed the system's limitations or if the encoder is reporting an abnormally high number of pulses.
Line Tracking Pulsecoder Disconnected
The line tracking Pulsecoder is not connected or its connection is faulty, preventing the system from receiving position feedback for line tracking operations.
Line Tracking Pulsecoder Backup Battery Not Connected
This alarm occurs if the backup battery for the absolute position of the line tracking Pulsecoder has not been connected. This can lead to loss of absolute position data upon power cycle.
Line Tracking Pulsecoder Backup Battery Low Voltage
This alarm occurs if the voltage of the backup battery for the absolute position of the line tracking Pulsecoder is low. A low battery voltage can lead to unstable absolute position data or loss of data upon power cycle.
Line Tracking Motor Overheat
The motor connected to the line tracking encoder has overheated. This alarm persists even after the Pulsecoder has cooled sufficiently and power is reapplied, indicating a persistent overheating condition or sensor issue.
Line Tracking Pulsecoder Communication Data Error
Communication between the Pulsecoder and the line tracking board is abnormal, specifically indicating a data error (DTERR). This prevents reliable position feedback for line tracking functions.
Line Tracking Pulsecoder Communication CRC Error
Communication between the Pulsecoder and the line tracking board is abnormal, specifically indicating a Cyclic Redundancy Check (CRC) error. This means data sent between the components is corrupted or inconsistent.
Line Tracking Pulsecoder Communication Start/Stop Bit Error
Communication between the Pulsecoder and the line tracking board is abnormal, specifically indicating a Start/Stop Bit Error (STBERR). This signifies a problem with the framing of serial data packets.
Line Tracking Pulsecoder Abnormally High Position Data
The current position data received from the Pulsecoder for line tracking is abnormally higher than the previous position data. This suggests an inconsistency or error in the position feedback, potentially due to a faulty Pulsecoder or signal interference.
PMAL alarm (Track Encoder Abnormality)
This alarm (Track enc:i) indicates that the Pulsecoder (track encoder) is likely abnormal, impacting the position feedback of the linear or rotary track. The underlying issue is an internal malfunction of the encoder.
CMAL alarm (Track Encoder Abnormality)
This alarm (Track enc:i) indicates that the Pulsecoder (track encoder) is likely abnormal or has malfunctioned due to noise. This will impact the accuracy and reliability of track encoder position feedback, potentially causing tracking errors. The root cause is similar to SRVO-073 for robot axes.
LDAL alarm (Track Encoder LED Broken)
This alarm (Track enc:i) indicates that the LED in the Pulsecoder (track encoder) is broken. This prevents the track encoder from generating proper position feedback, leading to loss of position control for the track. The cause and fix are identical to SRVO-074 for robot axes.
Pulse Not Established (Track Encoder)
This alarm (Enc:i) indicates that the absolute position of the Pulsecoder (track encoder) cannot be established. This typically occurs during startup or after a power cycle if the encoder's absolute position data is lost, preventing accurate track positioning. The cause and fix are identical to SRVO-075 for robot axes.
Door Open or Emergency Stop
This alarm indicates that the cabinet door is open or an emergency stop condition is active, triggering a safety interlock. This prevents robot operation until the safety condition is resolved, ensuring operator and equipment safety.
6-Axis Servo Amplifier Fuse Blown
A fuse (FS2 or FS3) within the 6-Axis servo amplifier has blown. This typically results from an overcurrent condition within the amplifier, possibly due to a motor short or internal component failure.
Total Overcurrent
The total current flowing through the motors for all six axes is excessively large. This usually indicates that the robot is operating beyond its specified duty cycle or maximum load weight ratings, or there's an electrical fault causing high current draw.
Missing DSP Axis Card
A controlled axis card (DSP) corresponding to the configured number of axes is not physically mounted or detected. This indicates a hardware configuration mismatch or a faulty axis control card.
DSP Initialization Failure / Dry Run Mode
A servo DSP initialization failure occurred due to either a hardware failure or an incorrect software setting, causing the system to enter DSP dry run mode. The first number in the alarm message provides details about the specific cause of the failure.
Safety Chain 1 Abnormal
A mismatch has occurred between duplicate safety signals. Specifically, a contact on the chain 1 side (e.g., between EES1 and EES11, or EAS1 and EAS11) is closed, while the corresponding contact on the chain 2 side (e.g., between EES2 and EES21, or EAS2 and EAS21) is open. This condition indicates a potential failure or discrepancy in one of the redundant safety circuits, compromising safety integrity.
Safety Chain 2 Abnormal
A mismatch has occurred between duplicate safety signals. Specifically, a contact on the chain 1 side (e.g., between EES1 and EES11, or EAS1 and EAS11) is open, while the corresponding contact on the chain 2 side (e.g., between EES2 and EES21, or EAS2 and EAS21) is closed. This condition indicates a potential failure or discrepancy in one of the redundant safety circuits, compromising safety integrity.
Teach Pendant Disabled in T1/T2 Mode
The teach pendant is disabled while the mode switch is set to T1 or T2, or the controller door is open. This safety interlock prevents unauthorized or unsafe operation in restricted modes or when the cabinet is open.
Short Term Single Chain Failure
A short-term single chain failure condition is detected. This can be caused by a momentary or 'half' release of the DEADMAN switch or a 'half' operation of the emergency stop switch, indicating a transient safety circuit anomaly.
Servo Amplifier Internal DB Relay Abnormal
An abnormality has been detected in the internal DB (Dynamic Braking) relay of the servo amplifier. This indicates a fault within the amplifier's internal circuitry responsible for dynamic braking.
Servo Amplifier Internal Alarm
The SVALM (Red) LED lights when the servo amplifier detects an internal alarm. This fault is indicated if the LED lights up when there is no apparent alarm condition in the machine, or if it does not light up when there *is* an alarm condition. This suggests a malfunction in the servo amplifier's internal diagnostic system or its alarm logic.
Emergency Stop Signal
The SVEMG (Red) LED indicates that an emergency stop signal is being input to the servo amplifier. This alarm occurs if the LED lights up when the machine is not in an emergency stop state, or if it fails to light when the machine *is* at an emergency stop. This indicates an internal issue with the servo amplifier's E-stop signal processing.
DC Link Not Charged
The V4 (Red) LED indicates that the DCLINK circuit inside the servo amplifier is charged to the specified voltage. If this LED does not light after the pre-charge sequence is finished, it suggests a problem with the DC link charging, potentially due to a short circuit or a defective charge current control resistor.
Attribute too long
This error indicates that an attribute (either its name or value) within an XML tag in the file being parsed has exceeded its maximum permissible length. This will disrupt the XML parsing process and data extraction.
No value for attribute
This fault occurs when an XML attribute is defined within a tag but is not assigned a corresponding value. All attributes must have a value in valid XML, and its absence will lead to parsing errors.
Unknown character &xxx;
This fault arises when an unrecognized or invalid XML entity reference (e.g., &xxx;) is encountered in the XML file. Valid entity references are either predefined (e.g., <, &) or declared in a DTD/schema, and unknown ones stop parsing.
Error in comment
This error indicates that there is a syntax problem within an XML comment block in the file. XML comments must start with <!-- and end with --> and cannot contain the sequence -- within the comment text itself.
Function code return
This fault indicates that an underlying internal function called during XML processing returned an error code. This is a generic indicator of a problem within one of the XML library's internal operations, preventing further parsing.
Invalid character in attribute
This fault indicates that an XML attribute contains characters that are not permitted within attribute names or values according to XML rules. Such characters disrupt the parsing of attribute information.
Unexpected end of file
This fault occurs when the XML parser reaches the end of the file unexpectedly, often indicating an incomplete or truncated XML document. This typically means an XML element or structure was left unclosed.
Invalid character in tag
This error indicates that an XML tag contains characters that are not allowed by XML naming conventions. XML tags must adhere to a strict set of character rules to be considered valid and parsable.
Cannot find file
This error signifies that the XML parser could not locate the specified XML file at the given path. This prevents any XML data from being loaded or processed by the system.
Invalid use of / character
This fault signifies an incorrect or misplaced use of the '/' character within the XML file structure. Proper XML syntax dictates specific locations for this character (e.g., self-closing tags, end tags), and its misuse will cause parsing to fail.
Scan limit exceeded
This error indicates that the XML file being processed is too large to be handled in a single parsing request. The XML scan routine has a defined limit for the amount of data it can scan at once, preventing complete processing in one go.
Tag too long
This error occurs when an XML tag within the parsed file exceeds the maximum allowed length, preventing the XML parsing process from completing successfully. This limitation helps manage memory and processing resources.
End tag with no matching start
This error means an XML end tag was encountered without a corresponding opening tag. This indicates an imbalance in the XML document structure, preventing proper parsing and hierarchical understanding of the data.
Tag nesting level too deep
This fault occurs when the hierarchical nesting of XML tags in the file exceeds the maximum allowed depth for the parser. Deeply nested XML structures can consume excessive resources or violate internal processing limits, leading to parsing failure.
Tag not found
This error indicates that a specific XML tag that was expected or searched for by the parsing routine was not found in the input XML file. This prevents the system from extracting anticipated data.