SRVO-214

6-Axis Servo Amplifier Fuse Blown

Fanuc · R-30iB Mate + Mate Plus Robot

¿Qué significa SRVO-214 ?

A fuse (FS2 or FS3) within the 6-Axis servo amplifier has blown. This typically results from an overcurrent condition within the amplifier, possibly due to a motor short or internal component failure.

Causas comunes

  • The fuse located within the 6-axis servo amplifier unit has blown.
  • This indicates an internal electrical fault or overload within the servo amplifier that has caused its protective fuse to activate.
  • Potential causes include a short circuit in the amplifier's power stage or motor wiring.
  • Requires opening the servo amplifier unit to inspect and replace the blown fuse, along with further diagnostics.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Identify and eliminate the cause of the blown fuse (FS2 or FS3).

  2. 2

    Replace the blown fuse (FS2 or FS3).

  3. 3

    Replace the 6-Axis servo amplifier.