Traduciendo...
12359
Read request is nested
Fanuc · R-30iA R-30iB Controller
¿Qué significa 12359 ?
A read request was initiated while another read request was already active for the same resource or file_id. This IO_STATUS error indicates an attempt to perform concurrent read operations which is not supported or allowed for the specific resource. The program will abort if the file_id is invalid.
Causas comunes
- Program logic error attempting multiple reads on the same file_id concurrently without proper synchronization or completion checks.
- Failure to properly complete or close a previous read request before initiating a new one.
- The file_id used does not correspond to a valid opened file, leading to confusion in state management.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review KAREL program logic to ensure read requests are handled sequentially for a given file_id and resource.
- 2
Verify that previous read operations are fully completed and their results processed before initiating new ones on the same resource.
- 3
Use the KAREL command READ file_id(cr) to clear any existing IO_STATUS error condition.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc R-30iA R-30iB Controller