Traduciendo...
12336
Cannot close pre_defined file
Fanuc · R-30iA R-30iB Controller
¿Qué significa 12336 ?
An attempt to close a pre-defined KAREL file (such as CRT/KB, teach pendant, or vision windows) failed. This IO_STATUS error indicates an issue preventing the proper release of these standard system I/O channels. This could leave the resource in an indeterminate state.
Causas comunes
- The specified pre-defined file is locked by another process or is in an invalid state, preventing its closure.
- System resources are preventing the proper closing of the file, such as a hung I/O operation.
- The pre-defined file was not properly opened in the first place, leading to an attempt to close an invalid handle.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the status of the specific pre-defined file (e.g., CRT/KB, teach pendant) to ensure it's in a closable state.
- 2
Check for any outstanding I/O operations on the pre-defined file that might be preventing its closure.
- 3
Use the KAREL command READ file_id(cr) to clear any existing IO_STATUS error condition.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc R-30iA R-30iB Controller