CC%2 SOM 4 not possible
Heidenhain · TNC CNC Controllers
¿Qué significa 231-A041 ?
This error indicates that Safety Operating Mode (SOM) 4 is not possible for the CC%2 controller. The common causes include Keylock Switch 1 not being in automatic mode (BA1), a defective Keylock Switch 1, or a wiring error.
Causas comunes
- Keylock switch 1 is not in automatic mode (BA1).
- Keylock switch 1 is defective.
- Wiring error related to Keylock switch 1.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Set Keylock switch 1 to automatic mode (BA1).
- 2
Test the functionality of Keylock switch 1; verify its different positions and their corresponding electrical signals.
- 3
Inspect the wiring connected to Keylock switch 1 for any breaks, shorts, or loose connections.
- 4
Measure continuity across the contacts of Keylock switch 1 in each position to confirm proper operation.