231-A002

Cancelation of brake-line-test call monitoring

Heidenhain · TNC CNC Controllers

¿Qué significa 231-A002 ?

This error indicates the cancellation of the brake-line-test call monitoring. The most common cause is that guard doors were open during the brake control test or brake line test, compromising safety.

Causas comunes

  • Guard door(s) were open during the brake control test or brake line test.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Ensure all guard doors are securely closed and locked before initiating and throughout the brake control test or brake line test.

  2. 2

    Verify the functionality of guard door interlocks and sensors.

  3. 3

    Check the wiring and connections related to the guard door safety circuit.

Ver todos los códigos en este manual (47)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas