Traduciendo...
231-A001

Cancelation of brake-test call monitoring

Heidenhain · TNC CNC Controllers

¿Qué significa 231-A001 ?

This error indicates that the brake-test call monitoring was canceled. This typically happens if protective doors are opened during the brake test, or if the drive-ready signal is not present during the monitoring period.

Causas comunes

  • Protective door(s) were opened during the brake test.
  • No drive-ready signal was present during the brake-test call monitoring.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Ensure all protective doors are closed and securely latched before and during the brake test.

  2. 2

    Verify that the drive is ready (drive-ready signal is active) before initiating and throughout the brake-test call monitoring.

  3. 3

    Check the status of safety door interlocks and associated sensors for correct operation.

  4. 4

    Inspect wiring for protective door switches and drive-ready signal for integrity and proper connection.

Ver todos los códigos en este manual (47)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Heidenhain TNC CNC Controllers