What does EC6:2 mean?
This return code, structured as Error class 6 (Access Error) and Error code 2 (Hardware fault), signifies an internal communication error within the system, specifically a hardware fault. The requested parameter service may not have been performed.
Common Causes
- Faulty connection on the internal communication bus (e.g., CAN, Profibus).
- Defective communication chip on the main controller or an I/O module.
- Signal integrity issues on the communication lines.
- Power supply instability affecting the communication hardware.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Repeat the parameter service request.
- 2
If the error occurs again, switch the drive inverter completely off (disconnect mains voltage and external DC 24V supply) and then back on again to force a re-initialization.
Verified technical data. Last updated: March 2026
Related Faults