Oversetter...
SV0366
PULSE MISS(INT)
Fanuc · Alpha i Series Servo Amplifier
Hva betyr SV0366 ?
A pulse error occurred on the built-in Pulsecoder, indicating that expected pulses were not detected. This impacts the accuracy of position feedback from the internal encoder.
Vanlige årsaker
- Interference on the pulse signal lines of the built-in Pulsecoder.
- Internal Pulsecoder encoder disk damage or slippage.
- Faulty signal generation within the built-in Pulsecoder.
- External noise affecting pulse signal integrity.
- Incorrect pulse output configuration in servo parameters.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Measure signal amplitude on internal Pulsecoder output terminals.
- 2
Inspect internal Pulsecoder encoder disk for scratches or misalignment.
- 3
Test internal Pulsecoder signal generation with a known good replacement if possible.
- 4
Filter incoming power to the servo drive to reduce noise.
- 5
Verify parameter P1-01 (Encoder Pulse Output) matches system requirements.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Fanuc Alpha i Series Servo Amplifier