Position Pulse Count Exceeded
Fanuc · Alpha i Series Servo Amplifier
Hva betyr 0243 ?
This invalid parameter setting alarm occurs when initialization bit 0 is set to 1, and the number of position pulses configured exceeds the maximum allowable value of 13100. This indicates an incorrect setup for position feedback, potentially leading to calculation overflows.
Vanlige årsaker
- Expected position pulses not received within the defined timeframe.
- Encoder disconnected or damaged.
- Motor moved unexpectedly without command.
- High vibration or shock affecting position feedback.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Correct the number of position pulses in the relevant parameter so that its value is within 13100.
- 2
If using a separate detector with fine resolution where the pulse count still exceeds 13100, utilize the position feedback pulse conversion coefficient.
- 3
Select a conversion coefficient B such that A (the number of position feedback pulses set in the parameter) is less than or equal to 32767.
- 4