0233
Velocity Pulse Count Exceeded
Fanuc · Alpha i Series Servo Amplifier
Hva betyr 0233 ?
This invalid parameter setting alarm occurs when initialization bit 0 is set to 1, and the number of velocity pulses configured exceeds the maximum allowable value of 13100. This indicates an incorrect setup for velocity feedback, potentially leading to calculation overflows.
Vanlige årsaker
- Expected velocity pulses not received within the defined timeframe.
- Encoder signal interruption or degradation.
- Motor not rotating as expected.
- Excessive lag in velocity feedback loop.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Correct the number of velocity pulses in the relevant parameter so that its value is within 13100.
Verifisert teknisk data. Sist oppdatert: March 2026