SP9076
INEXECUTION OF SAFETY FUNCTIONS
Fanuc · Alpha i Series Servo Amplifier
Hva betyr SP9076 ?
A safety function within the spindle system was not executed as expected. This indicates a critical software or hardware issue preventing safety routines from running, compromising spindle safety.
Vanlige årsaker
- Safety functions that should be active are not currently executing.
- Safety interlock circuit is open or deactivated.
- Safety PLC program logic has halted execution.
- Failure in a safety hardware component preventing function activation.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Replace the SPM control printed-circuit board.