Oversetter...
PW0012
USER I/O CROSS CHECK ERROR(DCS PMC)
Fanuc · Alpha i Series Servo Amplifier
Hva betyr PW0012 ?
The DCS PMC detected an error in the user-defined safe I/O cross-check function. This indicates a discrepancy in the monitored user-configured safe I/O signals, potentially affecting user-implemented safety features. A power cycle is required.
Vanlige årsaker
- DCS PMC detects inconsistency in user-defined safe I/O signals.
- Faulty user-programmed input or output device influencing safe I/O.
- DCS PMC internal error in comparing user-defined safe I/O states.
- Signal noise or interference on user-defined safe I/O lines.
- Incorrect configuration of user-defined safe I/O within the DCS PMC.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the status of all user-defined safe I/O signals on the DCS PMC.
- 2
Measure signal voltage at the DCS PMC user I/O terminals.
- 3
Verify parameter P1-18 (DCS PMC User I/O Configuration) for correct settings.
- 4
Inspect the wiring and connections of all user I/O devices.
- 5
Review user-defined logic that controls or monitors these I/O points.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Fanuc Alpha i Series Servo Amplifier