10043

Linear Motor Closed Loop Setting Error

Fanuc · Alpha i Series Servo Amplifier

Hva betyr 10043 ?

This invalid parameter setting alarm occurs when a linear motor is in use, and the closed loop is inadvertently set. For series other than the Series 9080, the closed loop function is incompatible with linear motors.

Vanlige årsaker

  • The initial configuration or calibration of the linear motor's closed-loop system failed.
  • Incorrect parameters are set for the linear motor's position feedback.
  • A physical limit switch or encoder setting is invalid.
  • The linear motor's internal reference point is not established correctly.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Adjust the parameter settings to disable the closed loop configuration when operating with a linear motor.

Se alle koder i denne manualen (101)