Oversetter...
0883
Serial Separate Detector Machine Velocity Feedback Coefficient Exceeded
Fanuc · Alpha i Series Servo Amplifier
Hva betyr 0883 ?
This invalid parameter setting alarm occurs for an axis equipped with a serial type separate detector when the machine velocity feedback coefficient is set to a value exceeding 100. The upper limit for this coefficient on such axes is strictly 100, and exceeding it causes an error.
Vanlige årsaker
- The machine velocity feedback coefficient has exceeded the maximum allowed value.
- The serial separate detector is reporting an excessively high velocity feedback.
- Parameter P601.1 (Serial Velocity Feedback Coefficient) is too high.
- An internal overflow occurred when processing the serial detector's velocity data.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Correct the machine velocity feedback coefficient so that its value does not exceed 100 for axes with a serial type separate detector.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Fanuc Alpha i Series Servo Amplifier