90

Incorrect motor/inverter assignment

SEW Eurodrive · Drives

¿Qué significa 90 ?

A mismatch has been detected between the assigned motor type and the MOVIMOT inverter. This indicates that the connected motor is incompatible with the inverter's configuration or capabilities.

Causas comunes

  • Incompatible motor connected to the MOVIMOT inverter
  • Incorrect motor type selection or parameterization in the drive settings

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the installed motor's nameplate data (e.g., model, power, voltage, current) against the MOVIMOT inverter's specified motor compatibility list and the intended motor assignment.

  2. 2

    Check and confirm all motor-specific parameters (e.g., nominal voltage, current, frequency, RPM, motor type selection) configured within the MOVIMOT inverter's software or HMI against the connected motor's nameplate.

  3. 3

    Inspect the physical wiring connections between the MOVIMOT inverter and the motor for correct phase assignment, secure termination, and any signs of damage or loose contacts that could affect motor identification.

  4. 4

    Verify the MOVIMOT inverter's model number and firmware version are appropriate for the connected motor type and application, referencing official SEW Eurodrive documentation.