Traduciendo...
01

Overcurrent in output stage

SEW Eurodrive · Drives

¿Qué significa 01 ?

An excessive current has been detected in the output stage of the MOVIMOT inverter. This typically indicates a short circuit, ground fault, or severe mechanical motor overload, causing the output current to exceed safe limits.

Causas comunes

  • Short circuit in the motor cable
  • Ground fault in the motor winding or cable
  • Severe mechanical overload on the motor

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect connected machinery and motor for any mechanical obstructions, jams, or signs of excessive load.

  2. 2

    Inspect the motor cable and terminal connections at both the MOVIMOT unit and the motor for physical damage, chafing, or loose terminations.

  3. 3

    Measure the insulation resistance of the motor windings and motor cable to ground using an appropriate insulation tester (Megger).

  4. 4

    Measure the phase-to-phase resistance of the motor windings (U-V, V-W, W-U) and compare readings for consistency.

  5. 5

    Verify MOVIMOT inverter parameters, specifically motor nominal current, overload factor, and acceleration/deceleration ramps, are correctly configured against motor nameplate data and application requirements.

Ver todos los códigos en este manual (39)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas