0C70

INTERBUS data transfer cancelled (MFI)

SEW Eurodrive · Drives

¿Qué significa 0C70 ?

The INTERBUS data transfer was cancelled, either because the initialization of the SUPI 3 protocol chip failed or the MFI is defective. This fault code can also be displayed if a reserved DIP switch setting is selected.

Causas comunes

  • Initialization of the INTERBUS protocol chip SUPI 3 failed.
  • Defective MFI (INTERBUS interface) hardware.
  • Invalid or reserved DIP switch setting selected on the MFI.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the DIP switch setting on the MFI for validity and ensure no reserved settings are selected.

  2. 2

    If the fault persists after verifying DIP switch settings, consider installing a new MFI electronic unit.