0BB4

MFI periphery fault history (PF TEN)

SEW Eurodrive · Drives

¿Qué significa 0BB4 ?

The MFI signals a periphery fault when a microprocessor reset has been carried out, typically due to EMC problems or defective hardware. This code logs the last 10 periphery faults, indicating intermittent or persistent issues.

Causas comunes

  • Microprocessor reset on the MFI due to EMC (Electromagnetic Compatibility) problems.
  • Defective hardware on the MFI electronic unit.
  • Interrupted or poor wiring/shielding for the MFI.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the wiring and shielding of the MFI for proper installation and integrity.

  2. 2

    Ensure the MFI is switched on and receiving proper power.

  3. 3

    If the fault reoccurs after checking wiring and power, install a new MFI electronic unit.

Ver todos los códigos en este manual (39)