Traduciendo...
445
Compatibility error (e.g. due to replacement of a PC board) / Invalid power stage set configuration
Fronius · Primo GEN24 Operating Instructions
¿Qué significa 445 ?
This code indicates a compatibility error, possibly due to a replaced PC board, or an invalid configuration of the power stage set. Either issue prevents the inverter from feeding energy into the grid, requiring a firmware update or configuration check.
Causas comunes
- Installation of an incompatible PC board.
- Incorrect configuration parameters for the power stage set.
- Firmware mismatch with the installed hardware components or configuration.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Update the inverter firmware to the latest compatible version.
- 2
If PC boards were recently replaced, verify they are the correct models for the inverter.
- 3
Check the power stage set configuration parameters for validity and correct them if necessary.
- 4
If the status code is displayed continuously, notify a Fronius-trained service engineer.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fronius Primo GEN24 Operating Instructions