408

DC component measured in the grid too high

Fronius · Primo GEN24 Operating Instructions

¿Qué significa 408 ?

This code indicates that an excessively high DC current component has been measured in the AC grid. Such a condition can indicate a fault within the inverter's power conversion stages or an external grid disturbance, typically causing the inverter to disconnect for safety.

Causas comunes

  • Internal fault within the inverter causing DC current injection into the AC grid.
  • Malfunction of grid monitoring relays or sensors detecting DC components.
  • Fault in the inverter's output filter or control.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer for diagnosis and repair.

  2. 2

    Perform an AC reset to cycle the inverter and clear transient measurement errors.

  3. 3

    Verify grid connection integrity and absence of external DC injection sources.