Traduciendo...
327
Fan 2 error
Fronius · Primo GEN24 Operating Instructions
¿Qué significa 327 ?
This code indicates an error with Fan 2, one of the inverter's internal cooling fans. A fan malfunction can lead to insufficient cooling and subsequent overtemperature conditions, causing a short-term interruption in energy feeding.
Causas comunes
- Fan 2 motor failure or blockage by debris.
- Faulty fan speed sensor or control circuit.
- Disconnection of the fan power supply or signal cable.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
If the status code is displayed continuously, notify a Fronius-trained service engineer for fan inspection and replacement.
- 2
Inspect Fan 2 for any visible obstructions or damage.
- 3
Perform an AC reset to attempt to clear transient fan control errors.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fronius Primo GEN24 Operating Instructions