Overtemperature in the connection area
Fronius · Primo GEN24 Operating Instructions
¿Qué significa 325 ?
This code indicates an overtemperature condition detected in the inverter's connection area. This suggests excessive heat at the terminals or wiring, causing a short-term interruption in energy feeding before the inverter attempts to restart.
Causas comunes
- Loose or corroded electrical connections generating localized heat.
- Overcurrent conditions in the connection area due to faulty wiring or undersized cables.
- Poor ventilation around the connection terminals.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
If this status code keeps recurring, contact your system engineer for diagnosis.
- 2
Inspect all electrical connections in the connection area for tightness and signs of overheating or damage.
- 3
Ensure adequate clearance and ventilation around the inverter's connection terminals.
- 4
Verify that cabling is correctly sized for the current draw.