U
Energy Supply Stop (ECM)
Fanuc · Alpha i Series AC Servo Motor and Spindle
Was bedeutet U ?
A potential difference across a capacitor module is more than 300V, indicating an energy supply issue or abnormal voltage condition.
Häufige Ursachen
- Charging current exceeds the allowed limit.
- Faulty charging circuit or power supply.
- Capacitor bank is not charging efficiently.
- Overcharging the capacitor module.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Measure the voltage across the capacitor modules to confirm it exceeds 300V.
- 2
Check the input power supply to the ECM for stable operation.
- 3
Verify the internal charging and discharge circuits of the ECM for proper voltage regulation.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc Alpha i Series AC Servo Motor and Spindle