Übersetzen...
1
Over-current at Power Running (ECM)
Fanuc · Alpha i Series AC Servo Motor and Spindle
Was bedeutet 1 ?
An over-current condition has occurred in the DC link during power running operation of the motor. This indicates excessive current draw, potentially due to motor load or amplifier issues.
Häufige Ursachen
- Excessive current drawn by the motor during normal acceleration or running phases.
- Motor is overloaded beyond its rated capacity.
- Mechanical issue causing increased motor torque requirement (e.g., binding, excessive friction).
- Incorrect motor tuning or acceleration profile settings (e.g., P1-03, P1-04).
- Voltage drop to the motor causing increased current draw.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the motor load during power running operation. Reduce if excessive.
- 2
Inspect the servo amplifier for any over-current related alarms.
- 3
Verify the DC link current sensors for proper operation.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc Alpha i Series AC Servo Motor and Spindle