SP0134
Soft Phase Alarm
Fanuc · Alpha i Series AC Servo Motor and Spindle
Was bedeutet SP0134 ?
An abnormal acceleration rate has been detected in the spindle motor. This indicates that the motor is accelerating too rapidly or outside its expected operational limits.
Häufige Ursachen
- Inconsistent or erroneous phase information from the motor controller.
- Faulty motor position sensor (e.g., Hall effect sensor, encoder).
- Incorrect motor winding configuration or connection.
- Software error in the drive's phase detection algorithm.
- High motor currents causing internal control instability.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review the spindle acceleration parameters (e.g., in parameter manual B-65280EN/06). Adjust if necessary.
- 2
Monitor the motor's acceleration profile during operation using diagnostic tools.
- 3
Check for mechanical issues like excessive load or binding that could cause abnormal acceleration.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026