Übersetzen...
F8120

Fatal Error (Initialization)

Bosch Rexroth · IndraDrive C Drive Controllers

Was bedeutet F8120 ?

This is a fatal error that occurs during the drive's initialization phase. When F8120 occurs, the closed-loop or open-loop U/f control of the drive is no longer guaranteed. The drive immediately switches off, becoming torque-free, overriding settings in P-0-0119 and P-0-0117. Fatal initialization errors cannot be cleared without a complete power cycle.

Häufige Ursachen

  • An error condition detected during the drive's initialization phase.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Switch the drive off completely.

  2. 2

    Clear the error message using command S-0-0099 (C0500 Reset class 1 diagnostics). This may require switching to parameter mode or a complete drive power cycle.

  3. 3

    Ensure the drive is in operating mode and power is switched on ("Ab").

  4. 4

    Switch on drive enable again (0-1 edge).

  5. 5

    If this fatal error recurs repeatedly, replacement of an entire component (e.g. motor or drive controller) may be necessary.

Alle Codes in diesem Handbuch durchsuchen (66)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Bosch Rexroth IndraDrive C Drive Controllers