Current limit active
Bosch Rexroth · IndraDrive C Drive Controllers
Was bedeutet E8041 ?
The motor current has reached its configured limit, indicating that the drive is trying to deliver maximum current but may not be able to achieve the commanded torque or speed due to load conditions.
Häufige Ursachen
- Motor running under excessive mechanical load, causing it to reach its current limit.
- Current limit parameter set too low for the application requirements.
- Mechanical binding or obstruction in the system, increasing required current.
- Drive parameter for current limit incorrectly set.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the mechanical load on the motor and ensure it is within the continuous current capability of the motor and drive.
- 2
Check the drive's current limit parameter and adjust if necessary, ensuring it is appropriate for the application.
- 3
Inspect the mechanical system for any binding, misalignment, or excessive friction that could increase the required current.
- 4
Monitor the actual motor current and torque values during operation to understand the load conditions.