E8040
Torque/force actual value limit active
Bosch Rexroth · IndraDrive C Drive Controllers
Was bedeutet E8040 ?
The actual torque or force developed by the motor has reached its configured limit. This warning indicates that the motor is operating at its maximum allowed output for torque/force.
Häufige Ursachen
- Motor running under excessive mechanical load, causing it to reach its torque limit.
- Torque limit parameter set too low for the application requirements.
- Mechanical binding or obstruction in the system, increasing required torque.
- Drive parameter for current/torque limit incorrectly set.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the mechanical load on the motor and ensure it is within the continuous torque capability of the motor and drive.
- 2
Check the drive's torque limit parameter and adjust if necessary, ensuring it is appropriate for the application.
- 3
Inspect the mechanical system for any binding, misalignment, or excessive friction that could increase the required torque.
- 4
Monitor the actual motor current and torque values during operation to understand the load conditions.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026