Übersetzen...
E2819
Mains failure
Bosch Rexroth · IndraDrive C Drive Controllers
Was bedeutet E2819 ?
Complete loss of incoming AC mains power supply to the drive. This results in an immediate loss of power to the control and power sections.
Häufige Ursachen
- Complete loss of incoming AC mains power.
- Main circuit breaker tripped or fuse blown for the entire supply.
- Emergency stop activated, cutting off mains power.
- Faulty power cable or connection.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the presence of incoming AC mains voltage at the drive's input terminals.
- 2
Check the main circuit breaker and any upstream protective devices for tripped conditions or blown fuses.
- 3
Inspect the mains power cabling from the supply point to the drive for any breaks or loose connections.
- 4
Confirm that no emergency stop or safety circuit has activated, cutting off the main power supply.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Bosch Rexroth IndraDrive C Drive Controllers