Übersetzen...
E2063

Velocity command value > limit value

Bosch Rexroth · IndraDrive C Drive Controllers

Was bedeutet E2063 ?

The commanded velocity exceeds the maximum allowable velocity configured for the axis. This prevents the drive from executing the command and can indicate an incorrect motion profile or parameter setting.

Häufige Ursachen

  • Programmed velocity command is higher than the drive's configured maximum velocity limit.
  • Incorrect scaling or unit conversion for velocity commands.
  • Encoder malfunction leading to incorrect velocity feedback interpretation.
  • Drive parameters for maximum velocity are set too low for the application.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the commanded velocity value in the motion program or HMI and ensure it is within the drive's configured maximum velocity limits.

  2. 2

    Verify the drive parameter for maximum velocity (e.g., S-0-0091) and adjust it if necessary, ensuring it is appropriate for the application and mechanical system.

  3. 3

    Inspect encoder cabling and connections, and verify encoder feedback for accuracy.

  4. 4

    Review the overall motion profile and acceleration/deceleration ramps to ensure commanded velocities are achievable.

Alle Codes in diesem Handbuch durchsuchen (66)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Bosch Rexroth IndraDrive C Drive Controllers