81
Start Condition Error (VFC Hoist)
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
What does 81 mean?
Immediate switch-off, specific to 'VFC hoist' operating mode, occurring when the motor cannot be supplied with the correct current during pre-magnetizing time. This typically happens if the rated motor power is too small relative to the inverter, or if the motor cable cross-section is insufficient.
Common Causes
- Start condition for VFC Hoist application is not met.
- Hoist motor cannot start due to safety or operational interlocks.
- Incomplete setup of hoist application parameters.
- External signal preventing hoist motor start.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check startup data and perform a new startup if necessary, ensuring the motor's rated power is compatible with the inverter's.
- 2
Check the connection between the inverter and the motor for any resistance or poor contact.
- 3
Check the cross-section of the motor cable and increase it if necessary to ensure adequate current delivery without excessive voltage drop.
Verified technical data. Last updated: March 2026
Related Faults
Source: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)