35
Operating Mode Not Defined
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
What does 35 mean?
Immediate switch-off because the inverter's operating mode (e.g., VFC, Servo, Positioning) is either not defined or incorrectly configured. The inverter cannot determine its fundamental control strategy.
Common Causes
- The drive's operating mode (e.g., V/f, Vector, Servo) is not configured.
- Attempting to operate in an undefined or invalid mode.
- Parameter setting for operating mode is missing or incorrect.
- Configuration error preventing the selection of a valid mode.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Use parameter P700 or P701 to set the correct operating mode.
Verified technical data. Last updated: March 2026
Related Faults
Source: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)