0012
Read access only
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
What does 0012 mean?
This PROFIBUS-DP additional code (Error Class 8, 'Other Error') occurs when an attempt was made to write to a parameter via PROFIBUS-DP that is designated as read-only. The inverter rejects the write request for parameters that cannot be modified.
Common Causes
- Attempting to write a value to a parameter that is configured for read-only access.
- Security setting prevents modification of this specific parameter.
- Parameter is dynamically set and cannot be manually overwritten.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.
Verified technical data. Last updated: March 2026
Related Faults
Source: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)