42

Lag Error

SEW Eurodrive · MOVIDRIVE compact MCF/MCV/MCS4_A

What does 42 mean?

Immediate switch-off because the actual position or speed of the motor is lagging too far behind its setpoint. Possible causes include an incorrectly connected encoder, overly short acceleration ramps, a P component of the positioning controller that is too small, incorrectly set speed controller parameters, a lag fault tolerance value that is too small, or mechanical binding in the system.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Set the P component (proportional gain) of the positioning controller to a higher value.

  2. 4

    Reset or finely tune speed controller parameters.

  3. 5

    Increase the lag fault tolerance value (e.g., P703, P704 for positioning tolerance).

  4. 6

    Check the wiring of the encoder, motor, and mains phases.

Source: SEW Eurodrive MOVIDRIVE compact MCF/MCV/MCS4_A