>ACS is on !

Anti Creeping Switch Operated

Otis · GAA21750AK3 Service Tool

What does >ACS is on ! mean?

This blinking event message indicates that the Anti Creeping Switch (ACS) is in an operated state, which has blocked the elevator. The ACS is a safety device designed to prevent unintended movement of the car when it is at a landing.

Common Causes

  • Mechanical actuation of the Anti Creeping Switch due to minor car movement or incorrect leveling.
  • Faulty Anti Creeping Switch wiring or internal failure.
  • Misalignment of the ACS triggering mechanism.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the elevator car is correctly leveled at the landing.

  2. 2

    Inspect the Anti Creeping Switch (ACS) for mechanical damage, obstruction, or misalignment.

  3. 3

    Check the wiring to the ACS for continuity and secure connections.

  4. 4

    Measure the state of the ACS contact using a multimeter to confirm open/closed status.

Browse all codes in this manual (15)
Verified technical data. Last updated: March 2026

Related Faults

Source: Otis GAA21750AK3 Service Tool