>1LS + 2LS !

Both 1LS and 2LS Operated

Otis · GAA21750AK3 Service Tool

What does >1LS + 2LS ! mean?

This blinking event message indicates that both Limit Switch 1 (1LS) and Limit Switch 2 (2LS) are simultaneously in an operated state, blocking elevator movement. This condition is typically indicative of an abnormal car position or a wiring fault within the OTIS 2000 Controllers MCS120/MCS220 system.

Common Causes

  • Incorrect car positioning leading to simultaneous actuation of both limit switches.
  • Short circuit or cross-wiring in the limit switch circuits.
  • Mechanical fault causing both switches to remain in an operated state.
  • Faulty individual limit switches, causing one or both to be stuck in an actuated position.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the elevator car's actual position relative to the limit switches 1LS and 2LS.

  2. 2

    Inspect 1LS and 2LS for physical damage or simultaneous mechanical actuation.

  3. 3

    Check wiring for 1LS and 2LS circuits for short circuits or incorrect connections.

  4. 4

    Measure the individual state of each limit switch contact to identify if one is stuck in an operated position.

Browse all codes in this manual (15)
Verified technical data. Last updated: March 2026

Related Faults

Source: Otis GAA21750AK3 Service Tool