SEW Eurodrive MOVI-PLC SyncCrane Application

9 feilkoder dokumentert

F29

Hardware Limit Switch Approached

This fault indicates that a hardware limit switch has been activated, causing the drive inverter to enter status F29. Ongoing movements are immediately interrupted using the emergency stop ramp to prevent mechanical damage or overtravel.

FF0201h

Invalid Number of Axes

This fault indicates that the SyncCrane application solution has been configured with an invalid number of axes. The system explicitly supports a maximum of 8 axes for control. Selecting more than 8 axes will trigger this error.

FF0202h

Invalid Axis Selection

This fault occurs when an invalid axis number is selected for control. For group control, Process Output Data word PO3 must be set to 99. For single axis control, PO3 must be set to a value between 1 and 8, corresponding to the specific axis.

FF0203h

Software Limit Switch CW Exceeded

This fault indicates that the specified position or the actual position of an axis has moved beyond the defined clockwise (CW) software limit switch. This condition prevents further movement in the CW direction and halts the axis system to prevent overtravel.

FF0204h

Software Limit Switch CCW Exceeded

This fault indicates that the specified position or the actual position of an axis has moved beyond the defined counter-clockwise (CCW) software limit switch. This condition prevents further movement in the CCW direction and halts the axis system to prevent overtravel.

FF0205h

Fieldbus Timeout

This fault signals an interruption in the fieldbus communication between the MOVI-PLC® and the master controller. When this timeout occurs, all internal setpoints are cleared to ensure a safe state for the axis system. This diagnostic function cyclically monitors bus communication.

FF0206h

External Encoder Implausible Values

This fault indicates that the external encoder is providing implausible position or feedback values to the MOVI-PLC® system. This can be caused by issues such as wire breakage in draw-wire encoders. Upon detection, the axis system is automatically stopped if operating in automatic mode.

FF0207h

HMI Communication Failure

This fault indicates that communication was interrupted while accessing the wizard via the Human-Machine Interface (HMI). When this communication failure occurs, all internal setpoints are cleared, potentially causing an operational halt of the axis system.

FF0208h

Lag Error Exceeded

This fault occurs when the defined lag error window is exceeded in automatic mode. The lag error represents the distance from the external encoder position to the virtual master encoder position. Exceeding this set tolerance causes the axis system to stop to maintain synchronized operation.