Oversetter...
99
IPOS Ramp Calculation Error
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Hva betyr 99 ?
Immediate switch-off in IPOS operating mode if the positioning ramp is configured as sinusoidal or square, and an attempt is made to change ramp times or traveling velocities while the inverter is already enabled. These parameters cannot be modified dynamically with these specific ramp types during active operation.
Vanlige årsaker
- Error in the IPOS ramp generation or calculation module.
- Invalid input parameters for acceleration/deceleration ramps in IPOS.
- Mathematical error during ramp profile computation.
- IPOS application trying to set impossible ramp profiles.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Rewrite the IPOS plus® program logic to ensure that ramp times and traveling velocities are only altered when the inverter is inhibited (not enabled).
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)