Oversetter...
0010
Illegal parameter index
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Hva betyr 0010 ?
This PROFIBUS-DP additional code (Error Class 8, 'Other Error') signifies the drive inverter received a parameter setting request with an invalid or non-existent parameter index. This suggests a misconfiguration in the parameter channel, potentially preventing proper drive operation.
Vanlige årsaker
- Attempting to access a parameter using an invalid index.
- Software error causing incorrect parameter addressing.
- External command referencing a non-existent parameter slot.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)