Oversetter...
88
Flying Start Speed Exceeded
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Hva betyr 88 ?
Immediate switch-off, specific to VFC n-CTRL operating mode, if the actual motor speed is detected to be greater than 5000 1/min when the inverter is enabled. The flying start function cannot engage at such high initial speeds.
Vanlige årsaker
- The motor speed during a flying start exceeded the allowed threshold.
- Attempting to synchronize with a rotating motor at too high a speed.
- Incorrect speed estimation or measurement during flying start.
- Parameter P1170 (Flying start speed) set too low or too high.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Ensure the inverter is not enabled for flying start until the actual motor speed is observed to be less than or equal to 5000 1/min.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)