Oversetter...
39
Reference Travel Error
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Hva betyr 39 ?
Immediate switch-off during reference travel because the reference cam is missing or not switching correctly, limit switches are connected incorrectly, or the reference travel type was changed while the process was active. This prevents the drive from accurately establishing its home position.
Vanlige årsaker
- Error during the reference travel (homing) sequence.
- Reference switch not detected or signal unstable during homing.
- Motor moved in the wrong direction during homing.
- Configuration parameters for reference travel are incorrect.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the reference cam for presence and proper switching functionality.
- 2
Verify the limit switch connections are correct.
- 3
Check the reference travel type setting and all required parameters for consistency and ensure no changes during active travel.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: SEW Eurodrive MOVIDRIVE compact System (MCF/MCV/MCS4_A)