Emergency Stop Timeout

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

Hva betyr 30 ?

Immediate switch-off because the drive is overloaded or the emergency stop ramp is configured too short. The drive is unable to decelerate to a stop within the programmed emergency stop time.

Vanlige årsaker

  • Emergency stop signal not received within the expected timeframe.
  • Emergency stop button remains pressed after acknowledgment.
  • Faulty wiring to the emergency stop input.
  • E-stop signal lost due to communication error.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review project planning parameters for appropriate drive sizing and emergency stop settings.

  2. 2

    Extend the emergency stop ramp time to allow for a longer deceleration period.