28

Fieldbus Timeout

SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)

Hva betyr 28 ?

Rapid stop caused by a loss of communication between the master and slave devices within the configured response monitoring time on the fieldbus. This signifies a disruption in fieldbus data exchange.

Vanlige årsaker

  • Communication with a fieldbus device has been interrupted.
  • Slave device is not responding on the fieldbus network.
  • Incorrect fieldbus address configuration.
  • Fieldbus network cable issue (e.g., termination, break).

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the communications routine and logic of the fieldbus master controller.

  2. 2

    Extend the fieldbus timeout time (P819) or, if appropriate for the application, temporarily deactivate monitoring to diagnose.