0019
Parameter access via RS-485 process interface on X13 only
SEW Eurodrive · MOVIDRIVE compact System (MCF/MCV/MCS4_A)
Hva betyr 0019 ?
This PROFIBUS-DP additional code (Error Class 8, 'Other Error') means parameter access was attempted via an incorrect communication interface. This specific parameter requires access through the RS-485 process interface on terminal X13, and the current access method is not permitted.
Vanlige årsaker
- Attempting to access process-related parameters via the diagnostic interface.
- Parameter modification via RS-485 is restricted to the X13 connector for process data.
- Incorrect communication interface used for parameterization of process variables.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check bits 0 and 1 in the PROFIBUS-DP parameter channel to ensure correct service code and length specification in the telegram.