OCF

OVERCURRENT

Schindler · Altivar 312 Drive

Hva betyr OCF ?

This overcurrent fault indicates that the motor current has exceeded the permissible limits, often due to incorrect drive or motor parameters, excessive mechanical load, or a mechanical locking condition. Sustained overcurrent can damage the motor or the drive.

Vanlige årsaker

  • Parameters in the [SETTINGS] (SEt-) and [MOTOR CONTROL] (drC-) menus are incorrect.
  • Inertia or load too high
  • Mechanical locking

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the parameters in [SETTINGS] (SEt-) , page 32, and [MOTOR CONTROL] (drC-) page 41.

  2. 2

    Check the size of the motor/drive/load.

  3. 3

    Check the state of the mechanism.

Se alle koder i denne manualen (32)