CFF
INCORRECT CONFIG.
Schindler · Altivar 312 Drive
Hva betyr CFF ?
This fault indicates that the current drive configuration is inconsistent, possibly due to the addition or removal of an option card. An inconsistent configuration can prevent proper drive operation.
Vanlige årsaker
- The drive's internal configuration data is inconsistent.
- An option card has been added to or removed from the drive without a configuration update.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Return the drive to its factory settings.
- 2
Retrieve and load a previously backed-up configuration, if it is valid. Refer to the [Restore config.] (FCS) parameter (page 46).
Verifisert teknisk data. Sist oppdatert: March 2026