941

MOTOR THERMOSTAT FAULT

Otis · DSD 412 Elevator System

Hva betyr 941 ?

This fault indicates that the DSD 412 drive has detected an open motor thermostat circuit, specifically between terminals A4TB3(2) and A4TB3(8). This condition does not automatically shut down the drive but is annunciated via the ALARM relay output K2.

Vanlige årsaker

  • The motor thermostat is open due to overheating or a circuit break.
  • If the thermostat contact point is closed but the fault persists, there may be a problem with the power supply.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the motor thermostat between terminals A4TB3(2) and A4TB3(8) for an open circuit.

  2. 2

    If the thermostat contact point is confirmed to be closed but the fault is still present, replace the power supply.

Se alle koder i denne manualen (57)
Verifisert teknisk data. Sist oppdatert: March 2026