Oversetter...
923
LOAD CURRENT SETTING FAULT
Otis · DSD 412 Elevator System
Hva betyr 923 ?
This fault is declared if a number entered for Rated Armature Current, #3, is outside the acceptable range of 0.125 to 2.0 times the bridge current rating. The bridge current rating is determined by the bridge sense resistor on the Cube ID PCB, located on the Armature Interface PCB. This fault requires a DSD power down.
Vanlige årsaker
- Rated Armature Current parameter #3 set outside the acceptable range relative to the bridge current rating.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Enter a valid number for Rated Armature Current, #3, within 0.125 to 2.0 times the bridge current rating (determined by the Cube ID PCB sense resistor).
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Otis DSD 412 Elevator System