Oversetter...
906

DCU FAILURE FAULT

Otis · DSD 412 DC Elevator Drive

Hva betyr 906 ?

The update mechanism for the Dual Port RAM from the Drive Control Unit (DCU) is unreliable. This condition necessitates the replacement of the Drive Control PCB (A1) and will shut down the DSD 412 drive. A power down is required.

Vanlige årsaker

  • Unreliable or intermittent updates from the Drive Control Unit (DCU) to the Dual Port RAM.
  • A faulty Drive Control PCB (A1).

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Perform a DSD 412 power down sequence.

  2. 2

    Replace the Drive Control PCB (A1).

Se alle koder i denne manualen (48)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Otis DSD 412 DC Elevator Drive